Patch-clamping is an electrophysiological recording technique that enables the investigation of single ion channel properties. Using patch clamping it is also possible to assess the electrical properties of small cells. Recordings are done with glass microelectrodes, similarly as in intracellular recording (althought the electrodes are not so sharp). The electrode glass forms an electrically and mechanically tight attachment to the lipids of the cell membrane, so-called giga-seal (referring to the Gigaohm resistance of the junction).
Patch-clamping is an electrophysiological recording technique that enables the investigation of single ion channel properties. Using patch clamping it is also possible to assess the electrical properties of small cells. Recordings are done with glass microelectrodes, similarly as in intracellular recording (althought the electrodes are not so sharp). The electrode glass forms an electrically and mechanically tight attachment to the lipids of the cell membrane, so-called giga-seal (referring to the Gigaohm resistance of the junction).



Revision as of 00:10, 23 September 2008

This article is a stub and thus not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

Patch-clamping is an electrophysiological recording technique that enables the investigation of single ion channel properties. Using patch clamping it is also possible to assess the electrical properties of small cells. Recordings are done with glass microelectrodes, similarly as in intracellular recording (althought the electrodes are not so sharp). The electrode glass forms an electrically and mechanically tight attachment to the lipids of the cell membrane, so-called giga-seal (referring to the Gigaohm resistance of the junction).

Depending of the configuration of the cell or cell membrane different variants are in use:

- cell-attached clamp (electrode is sealed to the cell membrane allowing investigation of possible ion channel activity on that spot of the membrane)

- whole-cell clamp (opening of the cell-attached part of the membrane) for voltage-clamping the whole cell or recording its responses in current-clamp mode)

- inside-out and

- outside-out configurations (where the cell patch is pulled from the cell, allowing it's detailed study).

Invention of patch-clamping is credited to Neher and Sakmann (1976) who got the Nobel prize in 1992 for this innovation.