User:Milton Beychok/Sandbox: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Milton Beychok
No edit summary
 
Line 1: Line 1:
A '''flue gas stack''' is a a vertical pipe, channel or similar structure through which [[combustion]] product gases called "flue gases" are exhausted to the outside air. Flue gas stacks are sometimes referred to as a "smokestacks".
{{AccountNotLive}}
__NOTOC__
[[File:Crude oil-fired power plant.jpg|thumb|right|225px|Industrial air pollution source]]
Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.  


Flue gases are produced when [[coal]], [[fuel oil]], [[natural gas]], [[wood]] or any other fuel is [[combustion|combusted]] in an industrial [[furnace]] or [[boiler]], a [[power plant]]'s [[steam-generator]], or other large combustion device. Flue gas is usually composed of [[carbon dioxide]] (CO<sub>2</sub>) and water vapor as well as [[nitrogen]] and excess [[oxygen]] remaining from the intake combustion air. It also contains a small percentage of pollutants such as [[particulate matter]], [[carbon monoxide]], [[nitrogen oxides]] and [[sulfur oxides]]. The flue gas stacks are often quite tall, up to 400 meters (1300 feet) or more, so as to disperse the exhaust [[pollutant]]s over a greater area and thereby reduce the [[ground-level concentration]] of the pollutants to comply with governmental [[air pollution]] control regulations.  
Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.<ref>J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", ''JAPCA'', Vol. 21, No. 7, 1971.</ref> 


When the flue gases are exhausted from stoves, ovens, fireplaces, or other small sources within residential abodes, restaurants, hotels, or other public buildings and small commercial enterprises, their flue gas stacks are referred to as "chimneys".
Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.


==History==
The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:


The first industrial chimneys were built in the mid-17th century when it was first understood how they could improve the combustion of a furnace by increasing the draft (draught) of air into the combustion zone. <ref>Douet, James (1988). ''Going up in Smoke:The History of the Industrial Chimney'', Victorian Society, London, England. [http://www.victoriansociety.org.uk/caserpts.html Victorian Society Casework Reports]</ref> As such, they played an important part in the development of [[reverberatory furnace]]s and a coal-based metallurgical industry, one of the key sectors of the early [[Industrial Revolution]]. Most 18th century industrial chimneys (now commonly referred to as flue gas stacks) were built into the walls of the furnace much like a domestic chimney. The first free-standing industrial chimneys were probably those erected at the end of the long condensing chimneys associated with smelting [[lead]].
* Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
* The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
* Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
* The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).


The powerful association between industrial chimneys and the characteristic smoke-filled landscapes of the industrial revolution was due the universal application of the [[steam engine]] for most manufacturing processes. The chimney is part of a steam-generating boiler, and its evolution is closely linked to increases in the power of the steam engine. The chimneys of Thomas Newcomen’s steam engine were incorporated into the walls of the engine house. The taller, free-standing industrial chimneys that appeared in the early 19th century were related to the changes in boiler design associated with James Watt’s "double-powered" engines, and they continued to grow in stature throughout the [[Victorian]] period. Decorative embellishments are a feature of many industrial chimneys  from the 1860s.
Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.


The invention of fan-assisted draft (draught) in the early 20th century removed the industrial chimney's original function, that of drawing air into the steam-generating boilers or other furnaces. With the replacement of the steam engine as a prime mover, first by [[diesel engine]]s and then by [[electric motor]]s, the  early industrial chimneys began to disappear from the industrial landscape. Building materials changed from stone and brick to steel and later reinforced concrete, and the height of the industrial chimney was determined by the need to disperse combustion flue gases to comply with governmental air pollution control regulations.
The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.


==Flue gas stack draft (or draught)==
==Atmospheric layers==


[[Image:Stack Effect.png|right|thumb|170px|{{#ifexist:Template:Stack Effect.png/credit|{{Stack Effect.png/credit}}<br/>|}}Outside and inside pressure difference causes draft in a flue gas stack. Light gray arrows indicate flue gas flow.]]
Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the ''troposphere''. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The ''stratosphere'' is the next layer and extends from 18 km up to about 50 km. The third layer is the ''mesosphere'' which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.


The combustion flue gases inside the flue gas stacks are much hotter than the ambient outside air and therefore less [[density|dense]] than the ambient air. That causes the bottom of the vertical column of hot flue gas to have a lower [[pressure]] than the pressure at the bottom of a corresponding column of outside air. That higher pressure outside the chimney is the driving force that moves the required combustion air into the combustion zone and also moves the flue gas up and out of the chimney.  That movement or flow of combustion air and flue gas is called "natural draft (or draught)", "natural ventilation", "chimney effect", or "stack effect". The taller the stack, the more draft (or draught) is created.
The lowest part of the troposphere is called the ''atmospheric boundary layer (ABL)'' or the ''planetary boundary layer (PBL)'' and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the ''inversion layer'' (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the ''free troposphere'' and it extends up to the 18 km height of the troposphere.


The equation below provides an approximation of the pressure difference, Δ''P'', (between the bottom and the top of the flue gas stack) that is created by the draft:<ref>[http://www.arch.hku.hk/teaching/lectures/airvent/sect02.htm Natural Ventilation Lecture 2]</ref><ref>{{cite book|author=Perry, R.H. and Green, Don W.|title=Perry's Chemical Engineers' Handbook|edition=6th Edition (page 9-72)|publisher=McGraw-Hill Book Company|year=1984|id=ISBN 0-07-049479-7}}</ref>
The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the ''mixing layer''. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.


:<math>\Delta P =\; C\, a\; h\; \bigg(\frac {1}{T_o} - \frac {1}{T_i}\bigg)</math>
In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as ''boundary layer models'' because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as ''mesoscale models'' have dispersion modeling capabilities that can extend horizontally as much as  a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.


:{| border="0" cellpadding="2"
==Gaussian air pollutant dispersion equation==
 
The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.<ref>C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", ''Trans. Faraday Soc.'', 32:1249, 1936.</ref> Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.
 
Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947<ref>O.G. Sutton, "The problem of diffusion in the lower atmosphere", ''QJRMS'', 73:257, 1947.</ref><ref>O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", ''QJRMS'', 73:426, 1947.</ref> which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.
 
Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the '''Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes''' shown below:<ref name=Beychok>{{cite book|author=M.R. Beychok|title=Fundamentals Of Stack Gas Dispersion|edition=4th Edition| publisher=author-published|year=2005|isbn=0-9644588-0-2}}.</ref><ref>{{cite book|author=D. B. Turner| title=Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling| edition=2nd Edition |publisher=CRC Press|year=1994|isbn=1-56670-023-X}}.</ref>
 
 
<math>C = \frac{\;Q}{u}\cdot\frac{\;f}{\sigma_y\sqrt{2\pi}}\;\cdot\frac{\;g_1 + g_2 + g_3}{\sigma_z\sqrt{2\pi}}</math>
 
{| border="0" cellpadding="2"  
|-
|-
|align=right|where:
|align=right|where:
|&nbsp;
|&nbsp;
|-
|-
!align=right| Δ''P''
!align=right|<math>f</math> 
|align=left|= available pressure difference, in [[Pascal (unit)|Pa]]
|align=left|= crosswind dispersion parameter
|-
!align=right|&nbsp;
|align=left|= <math>\exp\;[-\,y^2/\,(2\;\sigma_y^2\;)\;]</math>
|-
!align=right|<math>g</math>
|align=left|= vertical dispersion parameter = <math>\,g_1 + g_2 + g_3</math>
|-
!align=right|<math>g_1</math>
|align=left|= vertical dispersion with no reflections
|-
!align=right|&nbsp;
|align=left|= <math>\; \exp\;[-\,(z - H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_2</math>
|align=left|= vertical dispersion for reflection from the ground
|-
!align=right|&nbsp;
|align=left|= <math>\;\exp\;[-\,(z + H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_3</math>
|align=left|= vertical dispersion for reflection from an inversion aloft
|-
!align=right|&nbsp;
|align=left|= <math>\sum_{m=1}^\infty\;\big\{\exp\;[-\,(z - H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
|-
!align=right|''C''
!align=right|&nbsp;
|align=left|= 0.0342
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
|-
!align=right| ''a''
!align=right|&nbsp;
|align=left|= absolute [[atmospheric pressure]], in Pa
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z - H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]\big\}</math>
|-
|-
!align=right| ''h''
!align=right|<math>C</math>
|align=left|= height of the flue gas stack, in [[metres|m]]
|align=left|= concentration of emissions, in g/m³, at any receptor located:
|-
|-
!align=right| ''T<sub>o</sub>''
!align=right|&nbsp;
|align=left|= absolute outside air [[temperature]], in [[kelvin|K]]
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; x meters downwind from the emission source point
|-
|-
!align=right| ''T<sub>i</sub>''
!align=right|&nbsp;
|align=left|= absolute average temperature of the flue gas inside the stack, in K
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; y meters crosswind from the emission plume centerline
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; z meters above ground level
|-
!align=right|<math>Q</math>
|align=left|= source pollutant emission rate, in g/s
|-
!align=right|<math>u</math>
|align=left|= horizontal wind velocity along the plume centerline, m/s
|-
!align=right|<math>H</math>
|align=left|= height of emission plume centerline above ground level, in m
|-
!align=right|<math>\sigma_z</math>
|align=left|= vertical standard deviation of the emission distribution, in m
|-
!align=right|<math>\sigma_y</math>
|align=left|= horizontal standard deviation of the emission distribution, in m
|-
!align=right|<math>L</math>
|align=left|= height from ground level to bottom of the inversion aloft, in m
|-
!align=right|<math>\exp</math>
|align=left|= the exponential function
|}
|}


The above equation is an approximation because it assumes that the [[molar mass]] of the flue gas and the outside air are equal and that the pressure drop through the flue gas stack is quite small. Both assumptions are fairly good but not exactly accurate.
The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.
 
The sum of the four exponential terms in <math>g_3</math> converges to a final value quite rapidly. For most cases, the summation of the series with '''''m''''' = 1, '''''m''''' = 2 and '''''m''''' = 3 will provide an adequate solution.
 
<math>\sigma_z</math> and <math>\sigma_y</math> are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.


== The flue gas flow rate induced by the draft==
Whereas older models rely on stability classes for the determination of <math>\sigma_y</math> and <math>\sigma_z</math>, more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.


As a "first guess" approximation, the following equation can be used to estimate the flue gas flow rate induced by the draft of a flue gas stack. The equation assumes that the molar mass of the flue gas and the outside air are equal and that the [[friction|frictional resistance]] and heat losses are negligible:<ref>[http://www.arch.hku.hk/teaching/lectures/airvent/sect03.htm Natural Ventilation Lecture 3]</ref> <br><br>
==Briggs plume rise equations==


:<math>Q = C\; A\; \sqrt {2\;g\;H\;\frac{T_i - T_o}{T_i}}</math>
The Gaussian air pollutant dispersion equation (discussed above) requires the input of ''H'' which is the pollutant plume's centerline height above ground level. ''H'' is the sum of ''H''<sub>s</sub> (the actual physical height of the pollutant plume's emission source point) plus Δ''H'' (the plume rise due the plume's buoyancy).
{| border="0" cellpadding="2"
 
[[File:Gaussian Plume.png|thumb|right|333px|Visualization of a buoyant Gaussian air pollutant dispersion plume]]
 
To determine Δ''H'', many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.<ref>G.A. Briggs, "A plume rise model compared with observations", ''JAPCA'', 15:433–438, 1965.</ref> In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.<ref>G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", ''Atmos. Envir.'', 2:228–232, 1968.</ref> In that same year, Briggs also wrote the section of the publication edited by Slade<ref>D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.</ref> dealing with the comparative analyses of plume rise models.  That was followed in 1969 by his classical critical review of the entire plume rise literature,<ref>G.A. Briggs, "Plume Rise", ''USAEC Critical Review Series'', 1969.</ref> in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations".  Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.<ref>G.A. Briggs, "Some recent analyses of plume rise observation", ''Proc. Second Internat'l. Clean Air Congress'', Academic Press, New York, 1971.</ref><ref>G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", ''Atmos. Envir.'', 6:507–510, 1972.</ref>
 
Briggs divided air pollution plumes into these four general categories:
* Cold jet plumes in calm ambient air conditions
* Cold jet plumes in windy ambient air conditions
* Hot, buoyant plumes in calm ambient air conditions
* Hot, buoyant plumes in windy ambient air conditions
 
Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant.  Although Briggs proposed plume rise equations for each of the above plume categories, '''''it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes'''''.
 
In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants.  Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).
 
A logic diagram for using the Briggs equations<ref name=Beychok/> to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:
[[Image:BriggsLogic.png|none]]
:{| border="0" cellpadding="2"
|-
|-
|align=right|where:
|align=right|where:
|&nbsp;
|&nbsp;
|-
|-
!align=right| ''Q''
!align=right| Δh
|align=left|= flue gas flow rate, in m³/s 
|align=left|= plume rise, in m
|-
|-
!align=right| ''A''
!align=right| F<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= cross-sectional area of chimney, in m² (assuming it has a constant cross-section) 
|align=left|= buoyancy factor, in m<sup>4</sup>s<sup>−3</sup>
|-
|-
!align=right| ''C''
!align=right| x
|align=left|= discharge coefficient (usually taken to be from 0.65 to 0.70)
|align=left|= downwind distance from plume source, in m
|-
|-
!align=right| ''g''
!align=right| x<sub>f</sub>
|align=left|= [[standard gravity|gravitational acceleration]] at sea level, 9.807 m/s²
|align=left|= downwind distance from plume source to point of maximum plume rise, in m
|-
|-
!align=right| ''H''
!align=right| u
|align=left|= height of chimney, in m  
|align=left|= windspeed at actual stack height, in m/s
|-
|-
!align=right| ''T<sub>i</sub>''
!align=right| s<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->  
|align=left|= absolute average temperature of the flue gas in the stack, in [[kelvin|K]]
|align=left|= stability parameter, in s<sup>−2</sup>
|-
!align=right| ''T<sub>o</sub>''
|align=left|= absolute outside air temperature, in K 
|}
|}
The above parameters used in the Briggs' equations are discussed in Beychok's book.<ref name=Beychok/>


Designing chimneys and stacks to provide the correct amount of natural draft involves a great many factors such as:
==References==
 
{{reflist}}
* The height and diameter of the stack.
* The desired amount of excess combustion air needed to assure complete combustion.
* The temperature of the flue gases leaving the combustion zone.
* The composition of the combustion flue gas, which determines the flue gas [[density]].
* The frictional resistance to the flow of the flue gases through the chimney or stack, which will vary with the materials used to construct the chimney or stack.
* The heat loss from the flue gases as they flow through the chimney or stack.
* The local atmospheric pressure of the ambient air, which is determined by the local elevation above sea level.


The calculation of many of the above design factors requires trial-and-error reiterative methods.
== Further reading==


Governmental agencies in most countries have specific codes which govern how such design calculations must be performed. Many non-governmental organizations also have codes governing the design of chimneys and stacks (notably, the [[American Society of Mechanical Engineers|ASME]] codes).
*{{cite book | author=M.R. Beychok| title=Fundamentals Of Stack Gas Dispersion | edition=4th Edition | publisher=author-published | year=2005 | isbn=0-9644588-0-2}}


==Other items of interest==
*{{cite book | author=K.B. Schnelle and P.R. Dey| title=Atmospheric Dispersion Modeling Compliance Guide  | edition=1st Edition| publisher=McGraw-Hill Professional | year=1999 | isbn=0-07-058059-6}}


It should be noted that not all fuel-burning industrial equipment rely upon natural draft. Many such equipment items use large fans or blowers to accomplish the same objectives, namely: the flow of combustion air into the combustion chamber and the flow of the hot flue gas out of the chimney or stack.
*{{cite book | author=D.B. Turner| title=Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling | edition=2nd Edition | publisher=CRC Press | year=1994 | isbn=1-56670-023-X}}


A great many power plants are equipped with facilities for the removal of [[sulfur dioxide]] via [[flue gas desulfurization]]) as well as removal of [[nitrogen oxides]] (NO<sub>x</sub>) via [[selective catalytic reduction]], [[exhaust gas recirculation]], [[thermal deNOx]], or [[low NOx burner]]s.  
*{{cite book | author= S.P. Arya| title=Air Pollution Meteorology and Dispersion | edition=1st Edition | publisher=Oxford University Press | year=1998 | isbn=0-19-507398-3}}


In the United States and a number of other countries, [[atmospheric dispersion modeling]]<ref>{{cite book|author=Beychok, Milton R.|title=Fundamentals Of Stack Gas Dispersion|edition=4th Edition|publisher=author-published|year=2005|id=ISBN 0-9644588-0-2}} [http://www.air-dispersion.com www.air-dispersion.com]</ref> studies are required to determine the flue gas stack height needed to comply with the local air pollution regulations. The United States also limits the maximum height of a flue gas stack to what is known as the "Good Engineering Practice (GEP)" stack height.<ref>''Guideline for Determination of Good Engineering Practice Stack Height (Technical Support Document for the Stack Height Regulations), Revised'' (1985), EPA Publication No. EPA–450/4–80–023R, U.S. Environmental Protection Agency (NTIS No. PB 85–225241)</ref><ref>Lawson, Jr., R.E. and W.H. Snyder (1983). ''Determination of Good Engineering Practice Stack Height: A Demonstration Study for a Power Plant'', EPA Publication No. EPA–600/3–83–024. U.S. Environmental Protection Agency (NTIS No. PB 83–207407)</ref>  In the case of existing flue gas stacks that exceed the GEP stack height, any air pollution dispersion modeling studies for such stacks must use the GEP stack height rather than the actual stack height.
*{{cite book | author=R. Barrat| title=Atmospheric Dispersion Modelling | edition=1st Edition | publisher=Earthscan Publications | year=2001 | isbn=1-85383-642-7}}


==References==
*{{cite book | author=S.R. Hanna and R.E. Britter| title=Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites  | edition=1st Edition | publisher=Wiley-American Institute of Chemical Engineers | year=2002 | isbn=0-8169-0863-X}}
{{reflist}}


==External links==
*{{cite book | author=P. Zannetti| title=Air pollution modeling : theories, computational methods, and available software | edition= | publisher= Van Nostrand Reinhold | year=1990 | isbn=0-442-30805-1 }}
*[http://www.ashrae.org/publications/page/158 ASHRAE's Fundamentals Handbook] is available here from [[ASHRAE]]
*[http://www.asme.org/Codes/ ASME Codes and Standards] available from [[ASME]]
*[http://www.skyscraperpage.com/diagrams/?20374745 Diagram of 25 tallest flue gas stacks worldwide]

Latest revision as of 04:25, 22 November 2023


The account of this former contributor was not re-activated after the server upgrade of March 2022.


Industrial air pollution source

Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.

Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.[1]

Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.

The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:

  • Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
  • The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
  • Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
  • The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).

Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.

The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.

Atmospheric layers

Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the troposphere. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The stratosphere is the next layer and extends from 18 km up to about 50 km. The third layer is the mesosphere which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.

The lowest part of the troposphere is called the atmospheric boundary layer (ABL) or the planetary boundary layer (PBL) and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the inversion layer (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the free troposphere and it extends up to the 18 km height of the troposphere.

The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the mixing layer. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.

In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as boundary layer models because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as mesoscale models have dispersion modeling capabilities that can extend horizontally as much as a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.

Gaussian air pollutant dispersion equation

The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.[2] Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.

Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947[3][4] which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.

Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes shown below:[5][6]


where:  
= crosswind dispersion parameter
  =
= vertical dispersion parameter =
= vertical dispersion with no reflections
  =
= vertical dispersion for reflection from the ground
  =
= vertical dispersion for reflection from an inversion aloft
  =
           
           
           
= concentration of emissions, in g/m³, at any receptor located:
            x meters downwind from the emission source point
            y meters crosswind from the emission plume centerline
            z meters above ground level
= source pollutant emission rate, in g/s
= horizontal wind velocity along the plume centerline, m/s
= height of emission plume centerline above ground level, in m
= vertical standard deviation of the emission distribution, in m
= horizontal standard deviation of the emission distribution, in m
= height from ground level to bottom of the inversion aloft, in m
= the exponential function

The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.

The sum of the four exponential terms in converges to a final value quite rapidly. For most cases, the summation of the series with m = 1, m = 2 and m = 3 will provide an adequate solution.

and are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.

Whereas older models rely on stability classes for the determination of and , more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.

Briggs plume rise equations

The Gaussian air pollutant dispersion equation (discussed above) requires the input of H which is the pollutant plume's centerline height above ground level. H is the sum of Hs (the actual physical height of the pollutant plume's emission source point) plus ΔH (the plume rise due the plume's buoyancy).

Visualization of a buoyant Gaussian air pollutant dispersion plume

To determine ΔH, many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.[7] In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.[8] In that same year, Briggs also wrote the section of the publication edited by Slade[9] dealing with the comparative analyses of plume rise models. That was followed in 1969 by his classical critical review of the entire plume rise literature,[10] in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations". Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.[11][12]

Briggs divided air pollution plumes into these four general categories:

  • Cold jet plumes in calm ambient air conditions
  • Cold jet plumes in windy ambient air conditions
  • Hot, buoyant plumes in calm ambient air conditions
  • Hot, buoyant plumes in windy ambient air conditions

Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant. Although Briggs proposed plume rise equations for each of the above plume categories, it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes.

In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants. Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).

A logic diagram for using the Briggs equations[5] to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:

BriggsLogic.png
where:  
Δh = plume rise, in m
F  = buoyancy factor, in m4s−3
x = downwind distance from plume source, in m
xf = downwind distance from plume source to point of maximum plume rise, in m
u = windspeed at actual stack height, in m/s
s  = stability parameter, in s−2

The above parameters used in the Briggs' equations are discussed in Beychok's book.[5]

References

  1. J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", JAPCA, Vol. 21, No. 7, 1971.
  2. C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", Trans. Faraday Soc., 32:1249, 1936.
  3. O.G. Sutton, "The problem of diffusion in the lower atmosphere", QJRMS, 73:257, 1947.
  4. O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", QJRMS, 73:426, 1947.
  5. 5.0 5.1 5.2 M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. .
  6. D. B. Turner (1994). Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. .
  7. G.A. Briggs, "A plume rise model compared with observations", JAPCA, 15:433–438, 1965.
  8. G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", Atmos. Envir., 2:228–232, 1968.
  9. D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.
  10. G.A. Briggs, "Plume Rise", USAEC Critical Review Series, 1969.
  11. G.A. Briggs, "Some recent analyses of plume rise observation", Proc. Second Internat'l. Clean Air Congress, Academic Press, New York, 1971.
  12. G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", Atmos. Envir., 6:507–510, 1972.

Further reading

  • M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. 
  • K.B. Schnelle and P.R. Dey (1999). Atmospheric Dispersion Modeling Compliance Guide, 1st Edition. McGraw-Hill Professional. ISBN 0-07-058059-6. 
  • D.B. Turner (1994). Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. 
  • S.P. Arya (1998). Air Pollution Meteorology and Dispersion, 1st Edition. Oxford University Press. ISBN 0-19-507398-3. 
  • R. Barrat (2001). Atmospheric Dispersion Modelling, 1st Edition. Earthscan Publications. ISBN 1-85383-642-7. 
  • S.R. Hanna and R.E. Britter (2002). Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites, 1st Edition. Wiley-American Institute of Chemical Engineers. ISBN 0-8169-0863-X. 
  • P. Zannetti (1990). Air pollution modeling : theories, computational methods, and available software. Van Nostrand Reinhold. ISBN 0-442-30805-1.