A '''centrifugal fan''' (also referred to as a '''squirrel-cage fan''') is a mechanical device for moving [[air]] or other [[gas]]es. As shown in Figure 1, it has a wheel composed of a number of blades mounted around a hub that turns on a [[drive shaft]] passing  through the fan housing. The gas enters from the side of the wheel, turns 90 degrees and accelerates due to [[centrifugal force]] as it flows over the fan blades and exits the fan housing.<ref name=EPA>[http://www.epa.gov/apti/bces/module5/fans/types/types.htm#types Fan types] ([[U.S. EPA]] website page)</ref>
__NOTOC__
[[File:Crude oil-fired power plant.jpg|thumb|right|225px|Industrial air pollution source]]
Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.  


Centrifugal fans can generate [[pressure]] rises in the gas stream. They are commonly used to move the air in central heating and cooling systems. They are also used in some [[air pollution]] control systems as well as in various industrial processes
Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.<ref>J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", ''JAPCA'', Vol. 21, No. 7, 1971.</ref> 


==Fan components==
Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.


The major components of a typical centrifugal fan include the fan wheel, fan housing, drive mechanism, and inlet and/or outlet [[damper]]s.
The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:


===Types of drive mechanisms===
* Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
* The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
* Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
* The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).


The fan drive determines the rotational speed of the fan wheel and the extent to which this speed can be varied. There are three basic types of fan drives.<ref name=EPA/>
Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.


====Direct drive====
The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.


The fan wheel can be linked directly to the shaft of an [[electric motor]]. This means that the fan wheel speed is identical to the motor's rotational speed. With this type of fan drive mechanism, the fan speed cannot be varied unless the motor speed is adjustable.
==Atmospheric layers==


[[Image:Centrifugal fan belt drive.png|right|thumb|250px|{{#ifexist:Template:Centrifugal fan belt drive.png/credit|{{Centrifugal fan belt drive.png/credit}}<br/>|}}Figure 2: Belt-driven centrifugal fan.]]
Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the ''troposphere''. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The ''stratosphere'' is the next layer and extends from 18 km up to about 50 km. The third layer is the ''mesosphere'' which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.
====Belt drive====


As shown in Figure 2, belt driven fans use multiple belts that rotate in a set of [[sheave]]s mounted on the motor shaft and the fan wheel shaft. The belts transmit the mechanical [[energy]] from the motor to the fan.  
The lowest part of the troposphere is called the ''atmospheric boundary layer (ABL)'' or the ''planetary boundary layer (PBL)'' and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the ''inversion layer'' (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the ''free troposphere'' and it extends up to the 18 km height of the troposphere.


The fan wheel rotational speed (expressed in revolutions per minute, abbreviated as RPM) depends upon the ratio of the motor sheave diameter to the diameter of the fan wheel sheave and can be obtained from this equation:<ref name=EPA/>
The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the ''mixing layer''. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.


<math>rpm_\mathrm{\,fan} = rpm_\mathrm{\,motor}\,\bigg(\frac{\,D_\mathrm{motor}}{D_\mathrm{fan}}\bigg)</math>
In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as ''boundary layer models'' because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as ''mesoscale models'' have dispersion modeling capabilities that can extend horizontally as much as  a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.


{| border="0" cellpadding="2"
==Gaussian air pollutant dispersion equation==
 
The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.<ref>C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", ''Trans. Faraday Soc.'', 32:1249, 1936.</ref> Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.
 
Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947<ref>O.G. Sutton, "The problem of diffusion in the lower atmosphere", ''QJRMS'', 73:257, 1947.</ref><ref>O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", ''QJRMS'', 73:426, 1947.</ref> which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.
 
Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the '''Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes''' shown below:<ref name=Beychok>{{cite book|author=M.R. Beychok|title=Fundamentals Of Stack Gas Dispersion|edition=4th Edition| publisher=author-published|year=2005|isbn=0-9644588-0-2}}.</ref><ref>{{cite book|author=D. B. Turner| title=Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling| edition=2nd Edition |publisher=CRC Press|year=1994|isbn=1-56670-023-X}}.</ref>
 
 
<math>C = \frac{\;Q}{u}\cdot\frac{\;f}{\sigma_y\sqrt{2\pi}}\;\cdot\frac{\;g_1 + g_2 + g_3}{\sigma_z\sqrt{2\pi}}</math>
 
{| border="0" cellpadding="2"  
|-
|-
|align=left|where:
|align=right|where:
|&nbsp;
|&nbsp;
|-
|-
!align=right|<font style="vertical-align:-35%;"><math>rpm_\mathrm{\,fan}</math></font>
!align=right|<math>f</math> 
|align=left|= fan wheel speed in revolutions per minute
|align=left|= crosswind dispersion parameter
|-
!align=right|&nbsp;
|align=left|= <math>\exp\;[-\,y^2/\,(2\;\sigma_y^2\;)\;]</math>
|-
!align=right|<math>g</math>
|align=left|= vertical dispersion parameter = <math>\,g_1 + g_2 + g_3</math>
|-
!align=right|<math>g_1</math>
|align=left|= vertical dispersion with no reflections
|-
!align=right|&nbsp;
|align=left|= <math>\; \exp\;[-\,(z - H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_2</math>
|align=left|= vertical dispersion for reflection from the ground
|-
!align=right|&nbsp;
|align=left|= <math>\;\exp\;[-\,(z + H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_3</math>
|align=left|= vertical dispersion for reflection from an inversion aloft
|-
!align=right|&nbsp;
|align=left|= <math>\sum_{m=1}^\infty\;\big\{\exp\;[-\,(z - H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z - H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]\big\}</math>
|-
!align=right|<math>C</math>
|align=left|= concentration of emissions, in g/m³, at any receptor located:
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; x meters downwind from the emission source point
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; y meters crosswind from the emission plume centerline
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; z meters above ground level
|-
!align=right|<math>Q</math>
|align=left|= source pollutant emission rate, in g/s
|-
|-
!align=right|<font style="vertical-align:-35%;"><math>rpm_\mathrm{\,motor}</math></font>
!align=right|<math>u</math>
|align=left|= motor nameplate speed in revolutions per minute
|align=left|= horizontal wind velocity along the plume centerline, m/s
|-
|-
!align=right|<font style="vertical-align:-20%;"><math> D_\mathrm{motor}</math></font>
!align=right|<math>H</math>
|align=left|= diameter of the motor sheave
|align=left|= height of emission plume centerline above ground level, in m
|-
|-
!align=right|<font style="vertical-align:-20%;"><math>D_\mathrm{fan}</math></font>
!align=right|<math>\sigma_z</math>
|align=left|= diameter of the fan wheel sheave
|align=left|= vertical standard deviation of the emission distribution, in m
|-
!align=right|<math>\sigma_y</math>
|align=left|= horizontal standard deviation of the emission distribution, in m
|-
!align=right|<math>L</math>
|align=left|= height from ground level to bottom of the inversion aloft, in m
|-
!align=right|<math>\exp</math>
|align=left|= the exponential function
|}
|}


Fan wheel speeds in belt-driven fans are fixed unless the belts slip. Belt slippage can reduce the fan wheel speed several hundred revolutions per minute (rpm).
The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.


====Variable drive====
The sum of the four exponential terms in <math>g_3</math> converges to a final value quite rapidly. For most cases, the summation of the series with '''''m''''' = 1, '''''m''''' = 2 and '''''m''''' = 3 will provide an adequate solution.


Variable drive fans use [[hydraulic]] or [[magnetic]] couplings (between the fan wheel shaft and the motor shaft) that allow control of the fan wheel speed independent of the motor speed. The fan speed controls are often integrated into automated systems to maintain the desired fan wheel speed.<ref name=EPA/>
<math>\sigma_z</math> and <math>\sigma_y</math> are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.


An alternate method of varying the fan speed is by use of an electronic variable-speed drive which controls the speed of the motor driving the fan. This offers better overall energy efficiency at reduced speeds than hydraulic or magnetic couplings.
Whereas older models rely on stability classes for the determination of <math>\sigma_y</math> and <math>\sigma_z</math>, more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.


===Fan dampers===
==Briggs plume rise equations==


Fan dampers adjustable, movable plates used to control gas flow into and out of the centrifugal fan. They may be installed on the inlet side or on the outlet side of the fan, or both. Dampers on the outlet side impose a flow resistance used to control gas flow. Dampers on the inlet side are designed to control gas flow as well as to change how the gas enters the fan wheel.  
The Gaussian air pollutant dispersion equation (discussed above) requires the input of ''H'' which is the pollutant plume's centerline height above ground level. ''H'' is the sum of ''H''<sub>s</sub> (the actual physical height of the pollutant plume's emission source point) plus Δ''H'' (the plume rise due the plume's buoyancy).


Inlet dampers reduce fan energy usage due to their ability to affect the airflow pattern into the fan.<ref name=EPA/>
[[File:Gaussian Plume.png|thumb|right|333px|Visualization of a buoyant Gaussian air pollutant dispersion plume]]


===Fan blades===
To determine Δ''H'', many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.<ref>G.A. Briggs, "A plume rise model compared with observations", ''JAPCA'', 15:433–438, 1965.</ref> In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.<ref>G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", ''Atmos. Envir.'', 2:228–232, 1968.</ref> In that same year, Briggs also wrote the section of the publication edited by Slade<ref>D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.</ref> dealing with the comparative analyses of plume rise models. That was followed in 1969 by his classical critical review of the entire plume rise literature,<ref>G.A. Briggs, "Plume Rise", ''USAEC Critical Review Series'', 1969.</ref> in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations".  Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.<ref>G.A. Briggs, "Some recent analyses of plume rise observation", ''Proc. Second Internat'l. Clean Air Congress'', Academic Press, New York, 1971.</ref><ref>G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", ''Atmos. Envir.'', 6:507–510, 1972.</ref>
[[Image:Centrifugal fan blades.png|right|thumb|250px|{{#ifexist:Template:Centrifugal fan blades.png/credit|{{Centrifugal fan blades.png/credit}}<br/>|}}Figure 3: Types of centrifugal fan blades.]]


The fan wheel consists of a hub on which a number of fan blades are attached. The fan blades on the hub can be arranged in three different ways: forward-curved, backward-curved or radial.<ref name=EPA/>
Briggs divided air pollution plumes into these four general categories:
* Cold jet plumes in calm ambient air conditions
* Cold jet plumes in windy ambient air conditions
* Hot, buoyant plumes in calm ambient air conditions
* Hot, buoyant plumes in windy ambient air conditions


====Forward-curved blades====
Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant.  Although Briggs proposed plume rise equations for each of the above plume categories, '''''it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes'''''.


Forward-curved blades, as in Figure 3(a), use blades that curve in the direction of the fan wheel's rotation. These are especially sensitive to particulates. Forward-curved blades are for high flow, low pressure applications.
In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants.  Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).


====Backward-curved blades====
A logic diagram for using the Briggs equations<ref name=Beychok/> to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:
[[Image:BriggsLogic.png|none]]
:{| border="0" cellpadding="2"
|-
|align=right|where:
|&nbsp;
|-
!align=right| Δh
|align=left|= plume rise, in m
|-
!align=right| F<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= buoyancy factor, in m<sup>4</sup>s<sup>−3</sup>
|-
!align=right| x
|align=left|= downwind distance from plume source, in m
|-
!align=right| x<sub>f</sub>
|align=left|= downwind distance from plume source to point of maximum plume rise, in m
|-
!align=right| u
|align=left|= windspeed at actual stack height, in m/s
|-
!align=right| s<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= stability parameter, in s<sup>−2</sup>
|}
The above parameters used in the Briggs' equations are discussed in Beychok's book.<ref name=Beychok/>


Backward-curved blades, as in Figure 3(b), use blades that curve against the direction of the fan wheel's rotation. These types of fan wheels are used in fans designed to handle gas streams with relatively low particulate loadings because they are prone to solids build-up. Backward-curved fans are more energy efficient than radial blade fans. Backward curved blades are used for high pressure, low flow applications.
==References==
{{reflist}}


====Straight radial blades====
== Further reading==


Radial fan blades, as in Figure 3(c), extend straight out from the hub. A radial blade fan wheel is often used on particulate-laden gas streams because it is the least sensitive to solids build-up on the blades.
*{{cite book | author=M.R. Beychok| title=Fundamentals Of Stack Gas Dispersion | edition=4th Edition | publisher=author-published | year=2005 | isbn=0-9644588-0-2}}


==Centrifugal fan performance ratings==
*{{cite book | author=K.B. Schnelle and P.R. Dey| title=Atmospheric Dispersion Modeling Compliance Guide  | edition=1st Edition| publisher=McGraw-Hill Professional | year=1999 | isbn=0-07-058059-6}}


In the United States, tabulated fan ''performance ratings'' are available from fan manufacturers.<ref  name=CF>[http://www.cincinnatifan.com/catalogs/CPF-603-internet.pdf Direct Drive Rating Tables] (Scroll down to PDF page 6)</ref> For each of the manufacturer's fans, such tabulations list how much discharge pressure is created for a given volume of ''standard air'' handled by the fan and how much power must be provided by the fan's drive motor. The specific measurement units used in such tabulations are:
*{{cite book | author=D.B. Turner| title=Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling | edition=2nd Edition | publisher=CRC Press | year=1994 | isbn=1-56670-023-X}}


*Discharge static [[pressure]] created, denoted as (SP), in [[U.S. customary units|inches of water]] which may be denoted either as (in H<sub>2</sub>O), (" H<sub>2</sub>O) or ("). <small>[Note: 1 inch of water pressure is 248.8 Pa]</small>
*{{cite book | author= S.P. Arya| title=Air Pollution Meteorology and Dispersion | edition=1st Edition | publisher=Oxford University Press | year=1998 | isbn=0-19-507398-3}}


*Volume of ''standard air'' being handled in [[U.S. customary units|cubic feet]] per minute (CFM). <small>[Note: 1 cubic foot is 0.0283 m<sup>3 </sup>]</small>
*{{cite book | author=R. Barrat| title=Atmospheric Dispersion Modelling | edition=1st Edition | publisher=Earthscan Publications | year=2001 | isbn=1-85383-642-7}}
 
*The amount of power that must be provided by the fan's drive motor in [[U.S. customary units|brake horsepower]] (BHP). <small>[Note: 1 brake horsepower is 745.7 watts or 745.7 J/s]</small>
 
Fan manufacturers define ''standard air'' as clean, dry air at an absolute pressure of 14.696 [[U.S. customary units|psi]] (101.325 kPa) and a [[temperature]] of 70 °F (21 °C), which amounts to air at a standard [[Density (chemistry)|density]] of 0.075 [[U.S. customary units|lb]]/[[U.S. customary units|ft]]<sup>3</sup> (1.20 kg/m<sup>3</sup>). Thus, the fan ''performance rating'' tables are based on moving ''standard air'' at 70 °F and at an absolute pressure of 14.696 psi, and having a density of 0.075 lb/ft<sup>3</sup>.<ref name=CF/>
 
A centrifugal fan is a constant volume device that will move the same amount of air at two different temperatures. Thus, a centrifugal fan that moves 2,000 ft<sup>3</sup>/min (56 m<sup>3</sup>/min) at 70 °F (21 °C) will also move 2,000 ft<sup>3</sup>/min at 250 °F (121 °C).  However, since a given volume of 250 °F air weighs much less than the same volume of 70 °F air, the fan will create a lower discharge pressure and will require less drive motor power when moving the hotter air.
 
Thus, for example, when selecting a fan to handle 2,000 ft<sup>3</sup>/min at 250 °F, an ''air density correction factor'' must be applied to select the proper size fan to produce a discharge pressure of say 6 inches of water (1493 Pa). The ''air density correction factor'' is defined as the density of air at the standard temperature of 70 °F to the density of air at the non-standard conditions . In this example, since 250 °F air weighs only 75% of 70 °F air, the ''air density correction factor'' is  1.33 (i.e., 1.0 ÷ 0.75). Thus, the fan to be selected must be one rated to produce a discharge pressure of 8 inches of water (i.e., 1.33 × 6) when handling 2,000 ft<sup>3</sup>/min of ''standard air'' at 70 °F. If the ''performance rating'' table shows such a fan to require 4 brake horsepower, then the operating horsepower would only be 3 horsepower (i.e., 4 ÷ 1.33)  when handling the lighter air at 250 °F.
 
The product catalogs of most fan manufacturers usually contain a tabulation of ''air density correction factors'' that takes into account both the temperature of the air to be handled as well as the [[altitude]] at which the fan is to operate. Higher altitude locations have lower atmospheric air pressures and therefore lower air densities.<ref>[http://www.mpair.com/library.active/nyb.engineering.letters/engltr4.pdf Temperature and Altitude Affect Fan Selection]</ref>
 
==Air Movement and Control Association (AMCA)==
 
The centrifugal fan performance tables provide the fan RPM and power requirements for the given CFM and static pressure at standard air density. When the centrifugal fan performance is not at standard conditions, the performance must be converted to standard conditions before entering the performance tables. Centrifugal fans rated by the [[Air Movement and Control Association]] (AMCA) are tested in laboratories with test setups that simulate installations that are typical for that type of fan. Usually they are tested and rated as one of four standard installation types as designated in AMCA Standard 210.<ref>ANSI/AMCA Standard 210-99, "Laboratory Methods Of Testing Fans for Aerodynamic Performance Rating"</ref>
 
AMCA Standard 210 defines uniform methods for conducting laboratory tests on housed fans to determine airflow rate, pressure, power and efficiency, at a given speed of rotation. The purpose of AMCA Standard 210 is to define exact procedures and conditions of fan testing so that ratings provided by various manufacturers are on the same basis and may be compared.
 
==References==
{{reflist}}


==External links==
*{{cite book | author=S.R. Hanna and R.E. Britter| title=Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites  | edition=1st Edition | publisher=Wiley-American Institute of Chemical Engineers | year=2002 | isbn=0-8169-0863-X}}


*[http://www.amca.org/ Air Movement and Control Association website]
*{{cite book | author=P. Zannetti| title=Air pollution modeling : theories, computational methods, and available software | edition= | publisher= Van Nostrand Reinhold | year=1990 | isbn=0-442-30805-1 }}
*[http://www.processbarron.com/mechanical_draft_fans.aspx Centrifugal Fan Types and Fabrication by Process Barron]
*[http://www.greenheck.com/pdf/fans/FanFundamentalsMay2005.pdf Fan Fundamentals - A brief guide to selecting fans depending on the application by Greenheck Fan corporation]
*[http://www.mpair.com/library.active/nyb.engineering.letters/engltr4.pdf Temperature and Altitude Affect Fan Selection]
*[http://www.cincinnatifan.com/catalogs/EngData-203-internet.pdf Fan Engineering Data and Selection Guide by Cincinnati Fan]

Latest revision as of 04:25, 22 November 2023


The account of this former contributor was not re-activated after the server upgrade of March 2022.


Industrial air pollution source

Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.

Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.[1]

Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.

The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:

  • Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
  • The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
  • Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
  • The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).

Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.

The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.

Atmospheric layers

Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the troposphere. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The stratosphere is the next layer and extends from 18 km up to about 50 km. The third layer is the mesosphere which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.

The lowest part of the troposphere is called the atmospheric boundary layer (ABL) or the planetary boundary layer (PBL) and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the inversion layer (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the free troposphere and it extends up to the 18 km height of the troposphere.

The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the mixing layer. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.

In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as boundary layer models because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as mesoscale models have dispersion modeling capabilities that can extend horizontally as much as a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.

Gaussian air pollutant dispersion equation

The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.[2] Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.

Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947[3][4] which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.

Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes shown below:[5][6]


where:  
= crosswind dispersion parameter
  =
= vertical dispersion parameter =
= vertical dispersion with no reflections
  =
= vertical dispersion for reflection from the ground
  =
= vertical dispersion for reflection from an inversion aloft
  =
           
           
           
= concentration of emissions, in g/m³, at any receptor located:
            x meters downwind from the emission source point
            y meters crosswind from the emission plume centerline
            z meters above ground level
= source pollutant emission rate, in g/s
= horizontal wind velocity along the plume centerline, m/s
= height of emission plume centerline above ground level, in m
= vertical standard deviation of the emission distribution, in m
= horizontal standard deviation of the emission distribution, in m
= height from ground level to bottom of the inversion aloft, in m
= the exponential function

The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.

The sum of the four exponential terms in converges to a final value quite rapidly. For most cases, the summation of the series with m = 1, m = 2 and m = 3 will provide an adequate solution.

and are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.

Whereas older models rely on stability classes for the determination of and , more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.

Briggs plume rise equations

The Gaussian air pollutant dispersion equation (discussed above) requires the input of H which is the pollutant plume's centerline height above ground level. H is the sum of Hs (the actual physical height of the pollutant plume's emission source point) plus ΔH (the plume rise due the plume's buoyancy).

Visualization of a buoyant Gaussian air pollutant dispersion plume

To determine ΔH, many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.[7] In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.[8] In that same year, Briggs also wrote the section of the publication edited by Slade[9] dealing with the comparative analyses of plume rise models. That was followed in 1969 by his classical critical review of the entire plume rise literature,[10] in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations". Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.[11][12]

Briggs divided air pollution plumes into these four general categories:

  • Cold jet plumes in calm ambient air conditions
  • Cold jet plumes in windy ambient air conditions
  • Hot, buoyant plumes in calm ambient air conditions
  • Hot, buoyant plumes in windy ambient air conditions

Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant. Although Briggs proposed plume rise equations for each of the above plume categories, it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes.

In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants. Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).

A logic diagram for using the Briggs equations[5] to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:

BriggsLogic.png
where:  
Δh = plume rise, in m
F  = buoyancy factor, in m4s−3
x = downwind distance from plume source, in m
xf = downwind distance from plume source to point of maximum plume rise, in m
u = windspeed at actual stack height, in m/s
s  = stability parameter, in s−2

The above parameters used in the Briggs' equations are discussed in Beychok's book.[5]

References

  1. J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", JAPCA, Vol. 21, No. 7, 1971.
  2. C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", Trans. Faraday Soc., 32:1249, 1936.
  3. O.G. Sutton, "The problem of diffusion in the lower atmosphere", QJRMS, 73:257, 1947.
  4. O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", QJRMS, 73:426, 1947.
  5. 5.0 5.1 5.2 M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. .
  6. D. B. Turner (1994). Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. .
  7. G.A. Briggs, "A plume rise model compared with observations", JAPCA, 15:433–438, 1965.
  8. G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", Atmos. Envir., 2:228–232, 1968.
  9. D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.
  10. G.A. Briggs, "Plume Rise", USAEC Critical Review Series, 1969.
  11. G.A. Briggs, "Some recent analyses of plume rise observation", Proc. Second Internat'l. Clean Air Congress, Academic Press, New York, 1971.
  12. G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", Atmos. Envir., 6:507–510, 1972.

Further reading

  • M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. 
  • K.B. Schnelle and P.R. Dey (1999). Atmospheric Dispersion Modeling Compliance Guide, 1st Edition. McGraw-Hill Professional. ISBN 0-07-058059-6. 
  • D.B. Turner (1994). Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. 
  • S.P. Arya (1998). Air Pollution Meteorology and Dispersion, 1st Edition. Oxford University Press. ISBN 0-19-507398-3. 
  • R. Barrat (2001). Atmospheric Dispersion Modelling, 1st Edition. Earthscan Publications. ISBN 1-85383-642-7. 
  • S.R. Hanna and R.E. Britter (2002). Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites, 1st Edition. Wiley-American Institute of Chemical Engineers. ISBN 0-8169-0863-X. 
  • P. Zannetti (1990). Air pollution modeling : theories, computational methods, and available software. Van Nostrand Reinhold. ISBN 0-442-30805-1.