A '''gas compressor''' is a machine that increases the [[pressure]] of a [[gas]] by reducing its [[volume]].  
{{AccountNotLive}}
__NOTOC__
[[File:Crude oil-fired power plant.jpg|thumb|right|225px|Industrial air pollution source]]
Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.  


Compressors are used to raise the pressure of gases because gases are [[compressible fluid]]s. [[Pump]]s are used to raise the pressure of [[liquid]]s because liquids are practically incompressible. Compressors and pumps are similar in that both increase the pressure of a fluid and both can transport the fluid through [[piping]].<ref name=Trambouze>{{cite book|author=Pierre Trambouze|title= Petroleum Refining (Volume 4, Materials and Equipment)|edition=|publisher=Editions Technip|year=2000|id=ISBN 2-7108-0761-0}}</ref><ref name=Bloch>{{cite book|author=Heinz P. Bloch and Claire Soares|title=Process Plant Machinery|edition=2nd Edition|publisher=Butterworth and Heinemann|year=1998|id=ISBN 0-7506-7081-9}}</ref>
Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.<ref>J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", ''JAPCA'', Vol. 21, No. 7, 1971.</ref>


== Types of compressors ==
Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.


There are primarily two basic types of compressors. One type uses ''dynamic compression'' accomplished by the mechanical action of rotating countoured blades which impart velocity and hence pressure to the flowing gases. The other type uses ''positive displacement'' accomlished by trapping a volume of gas and displacing it by the action of a piston or a rotating member.
The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:


The dynamic compression compressors are sub-categorized as either [[centrifugal compressor]]s where the gas flows radially through the compressor or as [[axial compressor]]s where the gas flows straight through the compressor (parallel to the rotating drive shaft of the compressor).
* Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
* The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
* Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
* The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).


The positive displacement compressors are sub-categorized as either [[reciprocating compressor]]s or [[rotary compressor]]s and each of those include a number of different types.
Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.


The main types of gas compressors are illustrated in the chart below and each type is then discussed in the floowing sections:
The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.


[[Image:Compressor Types.png|center|thumb|510px|{{#ifexist:Template:Compressor Types.png/credit|{{Compressor Types.png/credit}}<br/>|}}Types of compressors.]]
==Atmospheric layers==


=== Centrifugal compressors ===
Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the ''troposphere''. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The ''stratosphere'' is the next layer and extends from 18 km up to about 50 km. The third layer is the ''mesosphere'' which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.


[[Image:Centrifugal Compressor.png|right|thumb|220px|{{#ifexist:Template:Centrifugal Compressor.png/credit|{{Centrifugal Compressor.png/credit}}<br/>|}}]]
The lowest part of the troposphere is called the ''atmospheric boundary layer (ABL)'' or the ''planetary boundary layer (PBL)'' and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the ''inversion layer'' (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the ''free troposphere'' and it extends up to the 18 km height of the troposphere.
[[Image:Centrifugal Compressor Impeller.jpg|right|thumb|250px|{{#ifexist:Template:Centrifugal Compressor Impeller.jpg/credit|{{Centrifugal Compressor Impeller.jpg/credit}}<br/>|}}Centrifugal compressor impeller inside a wedge diffuser]]
[[Image:Axial Compressor animation.gif|right|thumb|250px|{{#ifexist:Template:Axial Compressor animation.gif/credit|{{Axial Compressor animation.gif/credit}}<br/>|}}Animation of an axial compressor.]]


{{main|Centrifugal compressor}}
The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the ''mixing layer''. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.
'''Centrifugal compressors''' use a rotating disk or [[impeller]] in a shaped housing to force the gas to the rim of the impeller, increasing the velocity of the gas. A [[diffuser]] (divergent duct) section converts the velocity energy to pressure energy.  


The adjacent photograph is of a typical single-stage centrifugal compressor driven by an electrical motor.
In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as ''boundary layer models'' because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as ''mesoscale models'' have dispersion modeling capabilities that can extend horizontally as much as  a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.


They are very widely used for continuous, stationary service in industries such as [[Petroleum refining processes|petroleum refineries]], [[chemical plant|chemical]] and [[petrochemical]] plants, [[natural gas processing]] plants and many other industrial facilities.<ref name=Perry>{{cite book|author=Perry, R.H. and Green, D.W. (Editors)|title=[[Perry's Chemical Engineers' Handbook]]|edition=8th Edition|publisher=McGraw Hill|year=2007|id=ISBN 0-07-142294-3}}</ref><ref>{{cite book|author=Dixon S.L.|title=Fluid Mechanics, Thermodynamics of Turbomachinery|edition=Third Edition|publisher=Pergamon Press|year=1978|id=ISBN 0-08-022722-8}}</ref><ref>{{cite book|author=Aungier, Ronald H.|title=Centrifugal Compressors A Strategy for Aerodynamic design and Analysis|edition=|publisher=[[ASME]] Press|year=2000|id=ISBN 0-7918-0093-8}}</ref>
==Gaussian air pollutant dispersion equation==


Their applications can range from 100 hp (75 kW) to thousands of horsepower. With multiple staging, they can achieve extremely high output pressures greater than 10,000 psi (69 MPa).  
The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.<ref>C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", ''Trans. Faraday Soc.'', 32:1249, 1936.</ref> Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.


Many large snow-making operations (like [[ski resorts]]) use this type of compressor. They are also used in internal combustion engines as superchargers and [[turbocharger]]s. Centrifugal compressors are used in small [[gas turbine]] [[engine]]s or as the final compression stage of medium sized gas turbines.
Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947<ref>O.G. Sutton, "The problem of diffusion in the lower atmosphere", ''QJRMS'', 73:257, 1947.</ref><ref>O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", ''QJRMS'', 73:426, 1947.</ref> which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.


===Axial-flow compressors===
Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the '''Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes''' shown below:<ref name=Beychok>{{cite book|author=M.R. Beychok|title=Fundamentals Of Stack Gas Dispersion|edition=4th Edition| publisher=author-published|year=2005|isbn=0-9644588-0-2}}.</ref><ref>{{cite book|author=D. B. Turner| title=Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling| edition=2nd Edition |publisher=CRC Press|year=1994|isbn=1-56670-023-X}}.</ref>


{{main|Axial-flow compressor}}
'''Axial-flow compressors''' are dynamic rotating compressors that use arrays of fan-like [[aerofoils]] to progressively compress the working fluid.  They are used where there is a requirement for a high flows or a compact design.


The arrays of aerofoils are set in rows, usually as pairs: one rotating and one stationary. The rotating aerofoils, also known as blades or ''rotors'', accelerate the fluid. The stationary aerofoils, also known as a ''stators'' or vanes, turn and decelerate the fluid; preparing and redirecting the flow for the rotor blades of the next stage.<ref name=Perry/> Axial compressors are almost always multi-staged, with the cross-sectional area of the gas passage diminishing along the compressor to maintain an optimum axial [[Mach number]]. Beyond about 5 stages or a 4:1 design pressure ratio, [[variable geometry]] is normally used to improve operation.
<math>C = \frac{\;Q}{u}\cdot\frac{\;f}{\sigma_y\sqrt{2\pi}}\;\cdot\frac{\;g_1 + g_2 + g_3}{\sigma_z\sqrt{2\pi}}</math>


Axial compressors can have high efficiencies; around 90% [[polytropic]] at their design conditions. However, they are relatively expensive, requiring a large number of components, tight tolerances and high quality materials. Axial-flow compressors can be found in medium to large [[gas turbine]] engines, in natural gas pumping stations, and within certain chemical plants.
{| border="0" cellpadding="2"
|-
|align=right|where:
|&nbsp;
|-
!align=right|<math>f</math> 
|align=left|= crosswind dispersion parameter
|-
!align=right|&nbsp;
|align=left|= <math>\exp\;[-\,y^2/\,(2\;\sigma_y^2\;)\;]</math>
|-
!align=right|<math>g</math>
|align=left|= vertical dispersion parameter = <math>\,g_1 + g_2 + g_3</math>
|-
!align=right|<math>g_1</math>
|align=left|= vertical dispersion with no reflections
|-
!align=right|&nbsp;
|align=left|= <math>\; \exp\;[-\,(z - H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_2</math>
|align=left|= vertical dispersion for reflection from the ground
|-
!align=right|&nbsp;
|align=left|= <math>\;\exp\;[-\,(z + H)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|<math>g_3</math>
|align=left|= vertical dispersion for reflection from an inversion aloft
|-
!align=right|&nbsp;
|align=left|= <math>\sum_{m=1}^\infty\;\big\{\exp\;[-\,(z - H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z + H - 2mL)^2/\,(2\;\sigma_z^2\;)\;]</math>
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <math>+\, \exp\;[-\,(z - H + 2mL)^2/\,(2\;\sigma_z^2\;)\;]\big\}</math>
|-
!align=right|<math>C</math>
|align=left|= concentration of emissions, in g/m³, at any receptor located:
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; x meters downwind from the emission source point
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; y meters crosswind from the emission plume centerline
|-
!align=right|&nbsp;
|align=left|&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; z meters above ground level
|-
!align=right|<math>Q</math>
|align=left|= source pollutant emission rate, in g/s
|-
!align=right|<math>u</math>
|align=left|= horizontal wind velocity along the plume centerline, m/s
|-
!align=right|<math>H</math>
|align=left|= height of emission plume centerline above ground level, in m
|-
!align=right|<math>\sigma_z</math>
|align=left|= vertical standard deviation of the emission distribution, in m
|-
!align=right|<math>\sigma_y</math>
|align=left|= horizontal standard deviation of the emission distribution, in m
|-
!align=right|<math>L</math>
|align=left|= height from ground level to bottom of the inversion aloft, in m
|-
!align=right|<math>\exp</math>
|align=left|= the exponential function
|}


===Reciprocating compressors===
The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.


[[Image:Reciprocating Compressor.jpg|right|thumb|250px|{{#ifexist:Template:Reciprocating Compressor.jpg/credit|{{Reciprocating Compressor.jpg/credit}}<br/>|}}A motor-driven six-cylinder reciprocating compressor that can operate with two, four or six cylinders.]]
The sum of the four exponential terms in <math>g_3</math> converges to a final value quite rapidly. For most cases, the summation of the series with '''''m''''' = 1, '''''m''''' = 2 and '''''m''''' = 3 will provide an adequate solution.


{{main|Reciprocating compressor}}
<math>\sigma_z</math> and <math>\sigma_y</math> are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.
'''Reciprocating compressors''' use [[piston]]s driven by a crankshaft. They can be either stationary or portable, can be single or multi-staged, and can be driven by electric motors or internal combustion engines.<ref name=Perry/><ref>{{cite book|author=Bloch, H.P. and Hoefner, J.J.|title=Reciprocating Compressors, Operation and Maintenance|edition=|publisher=Gulf Professional Publishing|year=1996|id=ISBN 0-88415-525-0
}}</ref>
<ref>[http://www.machinerylubrication.com/article_detail.asp?articleid=775&pagetitle=Reciprocating%20Compressor%20Basics Reciprocating Compressor Basics] Adam Davis, Noria Corporation, ''Machinery Lubrication'', July 2005</ref> Small reciprocating compressors from 5 to 30&nbsp;[[horsepower]] (hp) are commonly seen in automotive applications and are typically for intermittent duty. Larger reciprocating compressors well over 1000 hp are still commonly found in large industrial and petroleum applications. Discharge pressures can range from low pressure to very high pressure (>5000 psi or 35 MPa). In certain applications, such as air compression, multi-stage double-acting compressors are said to be the most efficient compressors available, and are typically larger, noisier, and more costly than comparable rotary units.<ref>[http://www.compressedairchallenge.org/content/library/sourcebook/html/intro_ca.htm Introduction to Industrial Compressed Air Systems]</ref>


===Rotary screw compressors===
Whereas older models rely on stability classes for the determination of <math>\sigma_y</math> and <math>\sigma_z</math>, more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.


[[Image:Rotary Screw Compressor.gif|right|thumb|350px|{{#ifexist:Template:Rotary Screw Compressor.gif/credit|{{Rotary Screw Compressor.gif/credit}}<br/>|}}Diagram of a rotary screw compressor system]]
==Briggs plume rise equations==
[[Image:Screw Compressor Male and Female Screws.jpg|right|thumb|350px|{{#ifexist:Template:Screw Compressor Male and Female Screws.jpg/credit|{{Screw Compressor Male and Female Screws.jpg/credit}}<br/>|}}Photo of the screws in a two-screw compressor.]]


{{main|Rotary screw compressor}}
The Gaussian air pollutant dispersion equation (discussed above) requires the input of ''H'' which is the pollutant plume's centerline height above ground level. ''H'' is the sum of ''H''<sub>s</sub> (the actual physical height of the pollutant plume's emission source point) plus Δ''H'' (the plume rise due the plume's buoyancy).
'''Rotary screw compressors''' use two meshed rotating positive-displacement [[Helix|helical screws]] to force the gas into a smaller space.<ref name=Perry/><ref>[http://www.blackmer.com/tech-screw.jsp Screw Compressor] Describes how screw compressors work and include photographs.</ref><ref>[http://www.domnickhunter.com/tech_Centre.asp?chapter=1&section=3_Screw-Compressors_2_3.htm&getIndex=false Technical Centre] Discusses oil-flooded screw compressors including a complete system flow diagram</ref>


The adjacent photo the two screws within the compressor body: a female and a male screw. The female screw has inlets and the male screw has convex helical inlets. The screws rotate in opposite directions with the female screw receiving the driving power and transmitting this power to the male screw through a set of synchronization gears.
[[File:Gaussian Plume.png|thumb|right|333px|Visualization of a buoyant Gaussian air pollutant dispersion plume]]


As the screws rotate, the gas is drawn into the inlet port and fills up the space between the screws. The compression begins when the end of a male thread blocks the end of a female thread. The volume available between the compressor body and these two threads then progressively decreased during rotation. When this volume merges into the delivery outlet of the compressor, compressed gas is discharged from the compressor.
To determine Δ''H'', many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.<ref>G.A. Briggs, "A plume rise model compared with observations", ''JAPCA'', 15:433–438, 1965.</ref> In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.<ref>G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", ''Atmos. Envir.'', 2:228–232, 1968.</ref> In that same year, Briggs also wrote the section of the publication edited by Slade<ref>D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.</ref> dealing with the comparative analyses of plume rise models.  That was followed in 1969 by his classical critical review of the entire plume rise literature,<ref>G.A. Briggs, "Plume Rise", ''USAEC Critical Review Series'', 1969.</ref> in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations".  Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.<ref>G.A. Briggs, "Some recent analyses of plume rise observation", ''Proc. Second Internat'l. Clean Air Congress'', Academic Press, New York, 1971.</ref><ref>G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", ''Atmos. Envir.'', 6:507–510, 1972.</ref>


Screw compressors are typically used for continuous operation in commercial and industrial applications and may be either stationary or portable. Their applications range from 3 hp (2.24 kW) to over 500 hp (375 kW) and from low pressure to very high pressure (>1200 psi or 8.3 MPa).
Briggs divided air pollution plumes into these four general categories:
* Cold jet plumes in calm ambient air conditions
* Cold jet plumes in windy ambient air conditions
* Hot, buoyant plumes in calm ambient air conditions
* Hot, buoyant plumes in windy ambient air conditions


===Rotary vane compressors===
Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant.  Although Briggs proposed plume rise equations for each of the above plume categories, '''''it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes'''''.


{{See also|Rotary vane pump}}
In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants.  Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).


'''Rotary vane compressors''' consist of a rotor with a number of blades inserted in radial slots in the rotor. The rotor is mounted offset in a larger housing which can be circular or a more complex shape. As the rotor turns, blades slide in and out of the slots keeping contact with the outer wall of the housing.<ref name=Perry/> Thus, a series of decreasing volumes is created by the rotating blades. Rotary Vane compressors are, with piston compressors one of the oldest of compressor technologies.
A logic diagram for using the Briggs equations<ref name=Beychok/> to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:
[[Image:BriggsLogic.png|none]]
:{| border="0" cellpadding="2"
|-
|align=right|where:
|&nbsp;
|-
!align=right| Δh
|align=left|= plume rise, in m
|-
!align=right| F<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= buoyancy factor, in m<sup>4</sup>s<sup>−3</sup>
|-
!align=right| x
|align=left|= downwind distance from plume source, in m
|-
!align=right| x<sub>f</sub>
|align=left|= downwind distance from plume source to point of maximum plume rise, in m
|-
!align=right| u
|align=left|= windspeed at actual stack height, in m/s
|-
!align=right| s<sup>&nbsp;</sup> <!-- The HTML is needed to line up characters. Do not remove.-->
|align=left|= stability parameter, in s<sup>−2</sup>
|}
The above parameters used in the Briggs' equations are discussed in Beychok's book.<ref name=Beychok/>


With suitable port connections, the devices may be either a compressor or a vacuum pump.  They can be either stationary or portable, can be single or multi-staged, and can be driven by electric motors or internal combustion engines. Dry vane machines are used at relatively low pressures (e.g., 2 bar) for bulk material movement whilst oil-injected machines have the necessary volumetric efficiency to achieve pressures up to about 13 bar in a single stage. A rotary vane compressor is well suited to electric motor drive and is significantly quieter in operation than the equivalent piston compressor.
==References==
 
{{reflist}}
===Scroll compressors===
 
{{main|Scroll compressor}}
A '''scroll compressor''', also known as '''scroll pump''' and '''scroll vacuum pump''', uses two interleaved spiral-like vanes to [[pump]] or [[Gas compressor|compress]] [[fluid]]s such as [[liquids]] and [[gas]]es. The vane geometry may be [[involute]], [[archimedean spiral]], or hybrid curves.<ref>Tischer, J., Utter, R: “Scroll Machine Using Discharge Pressure For Axial Sealing,” U.S. Patent 4522575, 1985.</ref><ref>Caillat, J., Weatherston, R., Bush, J: “Scroll-Type Machine With Axially Compliant Mounting,” U.S. Patent 4767293, 1988.</ref><ref>Richardson, Jr., Hubert: “Scroll Compressor With Orbiting Scroll Member Biased By Oil Pressure,” U.S. Patent 4875838, 1989.</ref> They operate more smoothly, quietly, and reliably than other types of compressors in the lower volume range


Often, one of the scrolls is fixed, while the other orbits eccentrically without rotating, thereby trapping and pumping or compressing pockets of fluid or gas between the scrolls.
== Further reading==


===Diaphragm compressors===
*{{cite book | author=M.R. Beychok| title=Fundamentals Of Stack Gas Dispersion | edition=4th Edition | publisher=author-published | year=2005 | isbn=0-9644588-0-2}}


[[Image:Diaphragm Compressor.jpg|right|thumb|250px|{{#ifexist:Template:Diaphragm Compressor.jpg/credit|{{Diaphragm Compressor.jpg/credit}}<br/>A three-stage diaphragm compressor]]
*{{cite book | author=K.B. Schnelle and P.R. Dey| title=Atmospheric Dispersion Modeling Compliance Guide  | edition=1st Edition| publisher=McGraw-Hill Professional | year=1999 | isbn=0-07-058059-6}}


{{main|Diaphragm compressor}}
*{{cite book | author=D.B. Turner| title=Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling | edition=2nd Edition | publisher=CRC Press | year=1994 | isbn=1-56670-023-X}}
A '''diaphragm compressor''' (also known as a '''membrane compressor''') is a variant of the conventional reciprocating compressor. The compression of gas occurs by the movement of a flexible membrane, instead of an intake element. The back and forth movement of the  membrane is driven by a rod and a crankshaft mechanism. Only the membrane and the compressor box come in touch with the gas being compressed.<ref name=Perry/>


Diaphragm compressors are used for hydrogen and compressed natural gas ([[Compressed natural gas|CNG]]) as well as in a number of other applications.
*{{cite book | author= S.P. Arya| title=Air Pollution Meteorology and Dispersion | edition=1st Edition | publisher=Oxford University Press | year=1998 | isbn=0-19-507398-3}}
 
The photograph included in this section depicts a three-stage diaphragm compressor used to compress [[hydrogen]] gas to 6,000 psi (41 MPa) for use in a prototype [[compressed hydrogen]] and [[compressed natural gas]] (CNG) fueling station built in downtown [[Phoenix, Arizona]] by the [[Arizona Public Service]] company (an electric utilities company). [[Reciprocating compressor]]s were used to compress the [[natural gas]].
 
The prototype [[alternative fuel]]ing station was built in compliance with all of the prevailing safety, environmental and building codes in Phoenix to demonstrate that such fueling stations could be built in urban areas.
 
== Compressor drivers==
 
There are many types of equipment, often referred to as ''prime movers'', which can be used to drive a compressor:
 
* [[Gas turbine]]s
* [[Steam turbine]]s 
* [[Electric motor]]s
* [[Natural gas engines]]
* [[Gasoline engine]]s
* [[Diesel engine]]s
* [[Hydraulic power]] systems
 
== Applications ==
 
Gas compressors are used in various applications where either higher gas pressures or lower volumes of gas are needed:
 
* in [[pipeline transport]] of purified natural gas to move the gas from the production site to the consumer.
* in petroleum refineries, natural gas processing plants, petrochemical and chemical plants, and similar large industrial plants for compressing intermediate and end product gases.
* in [[refrigeration]] and [[air conditioner]] equipment to move [[heat]] from one place to another in [[refrigerant]] cycles: see [[Vapor-compression refrigeration]].
* in gas turbine systems to compress the intake [[combustion]] air
* in storing purified or manufactured gases in small volume, high pressure cylinders for [[medical]], [[welding]] and other uses.
* in many various industrial, manufacturing and building processes to power all types of [[pneumatic tools]].
* in [[Cabin pressurization|pressurised]] aircraft to provide a breathable atmosphere of higher than ambient pressure.
* in some types of [[jet engine]]s (such as [[turbojet]]s and [[turbofan]]s) to provide the air required for combustion of the engine fuel. The power to drive the combustion air compressor comes from the jet's own [[turbine]]s.
* in [[SCUBA diving]], [[hyperbaric oxygen therapy]] and other life support devices to store [[breathing gas]] in a small volume such as in [[diving cylinder]]s.
* in [[submarine]]s, to store air for later use in displacing water from buoyancy chambers, for adjustment of depth.
* in [[turbocharger]]s and [[supercharger]]s to increase the performance of [[internal combustion engine]]s by increasing mass flow.
* in [[Rail transport|rail]] and heavy [[road transport]] to provide [[compressed air]] for operation of [[Air brake (rail)|rail vehicle brakes]] or [[Air brake (road vehicle)|road vehicle brakes]].
 
==References==


<references/>
*{{cite book | author=R. Barrat| title=Atmospheric Dispersion Modelling | edition=1st Edition | publisher=Earthscan Publications | year=2001 | isbn=1-85383-642-7}}


== See also ==
*{{cite book | author=S.R. Hanna and R.E. Britter| title=Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites  | edition=1st Edition | publisher=Wiley-American Institute of Chemical Engineers | year=2002 | isbn=0-8169-0863-X}}


* [[Vapor-compression refrigeration]]
*{{cite book | author=P. Zannetti| title=Air pollution modeling : theories, computational methods, and available software | edition= | publisher= Van Nostrand Reinhold | year=1990 | isbn=0-442-30805-1 }}

Latest revision as of 04:25, 22 November 2023


The account of this former contributor was not re-activated after the server upgrade of March 2022.


Industrial air pollution source

Atmospheric dispersion modeling is the mathematical simulation of how air pollutants disperse in the ambient atmosphere. It is performed with computer programs that solve the mathematical equations and algorithms which simulate the pollutant dispersion. The dispersion models are used to estimate or to predict the downwind concentration of air pollutants emitted from sources such as industrial plants, vehicular traffic or accidental chemical releases.

Such models are important to governmental agencies tasked with protecting and managing the ambient air quality. The models are typically employed to determine whether existing or proposed new industrial facilities are or will be in compliance with the National Ambient Air Quality Standards (NAAQS) in the United States or similar regulations in other nations. The models also serve to assist in the design of effective control strategies to reduce emissions of harmful air pollutants. During the late 1960's, the Air Pollution Control Office of the U.S. Environmental Protection Agency (U.S. EPA) initiated research projects to develop models for use by urban and transportation planners.[1]

Air dispersion models are also used by emergency management personnel to develop emergency plans for accidental chemical releases. The results of dispersion modeling, using worst case accidental releases and meteorological conditions, can provide estimated locations of impacted areas and be used to determine appropriate protective actions. At industrial facilities in the United States, this type of consequence assessment or emergency planning is required under the Clean Air Act (CAA) codified in Part 68 of Title 40 of the Code of Federal Regulations.

The dispersion models vary depending on the mathematics used to develop the model, but all require the input of data that may include:

  • Meteorological conditions such as wind speed and direction, the amount of atmospheric turbulence (as characterized by what is called the "stability class"), the ambient air temperature, the height to the bottom of any inversion aloft that may be present, cloud cover and solar radiation.
  • The emission parameters such the type of source (i.e., point, line or area), the mass flow rate, the source location and height, the source exit velocity, and the source exit temperature.
  • Terrain elevations at the source location and at receptor locations, such as nearby homes, schools, businesses and hospitals.
  • The location, height and width of any obstructions (such as buildings or other structures) in the path of the emitted gaseous plume as well as the terrain surface roughness (which may be characterized by the more generic parameters "rural" or "city" terrain).

Many of the modern, advanced dispersion modeling programs include a pre-processor module for the input of meteorological and other data, and many also include a post-processor module for graphing the output data and/or plotting the area impacted by the air pollutants on maps. The plots of areas impacted usually include isopleths showing areas of pollutant concentrations that define areas of the highest health risk. The isopleths plots are useful in determining protective actions for the public and first responders.

The atmospheric dispersion models are also known as atmospheric diffusion models, air dispersion models, air quality models, and air pollution dispersion models.

Atmospheric layers

Discussion of the layers in the Earth's atmosphere is needed to understand where airborne pollutants disperse in the atmosphere. The layer closest to the Earth's surface is known as the troposphere. It extends from sea-level up to a height of about 18 km and contains about 80 percent of the mass of the overall atmosphere. The stratosphere is the next layer and extends from 18 km up to about 50 km. The third layer is the mesosphere which extends from 50 km up to about 80 km. There are other layers above 80 km, but they are insignificant with respect to atmospheric dispersion modeling.

The lowest part of the troposphere is called the atmospheric boundary layer (ABL) or the planetary boundary layer (PBL) and extends from the Earth's surface up to about 1.5 to 2.0 km in height. The air temperature of the atmospheric boundary layer decreases with increasing altitude until it reaches what is called the inversion layer (where the temperature increases with increasing altitude) that caps the atmospheric boundary layer. The upper part of the troposphere (i.e., above the inversion layer) is called the free troposphere and it extends up to the 18 km height of the troposphere.

The ABL is the most important layer with respect to the emission, transport and dispersion of airborne pollutants. The part of the ABL between the Earth's surface and the bottom of the inversion layer is known as the mixing layer. Almost all of the airborne pollutants emitted into the ambient atmosphere are transported and dispersed within the mixing layer. Some of the emissions penetrate the inversion layer and enter the free troposphere above the ABL.

In summary, the layers of the Earth's atmosphere from the surface of the ground upwards are: the ABL made up of the mixing layer capped by the inversion layer; the free troposphere; the stratosphere; the mesosphere and others. Many atmospheric dispersion models are referred to as boundary layer models because they mainly model air pollutant dispersion within the ABL. To avoid confusion, models referred to as mesoscale models have dispersion modeling capabilities that can extend horizontally as much as a few hundred kilometres. It does not mean that they model dispersion in the mesosphere.

Gaussian air pollutant dispersion equation

The technical literature on air pollution dispersion is quite extensive and dates back to the 1930s and earlier. One of the early air pollutant plume dispersion equations was derived by Bosanquet and Pearson.[2] Their equation did not assume Gaussian distribution nor did it include the effect of ground reflection of the pollutant plume.

Sir Graham Sutton derived an air pollutant plume dispersion equation in 1947[3][4] which did include the assumption of Gaussian distribution for the vertical and crosswind dispersion of the plume and also included the effect of ground reflection of the plume.

Under the stimulus provided by the advent of stringent environmental control regulations, there was an immense growth in the use of air pollutant plume dispersion calculations between the late 1960s and today. A great many computer programs for calculating the dispersion of air pollutant emissions were developed during that period of time and they were commonly called "air dispersion models". The basis for most of those models was the Complete Equation For Gaussian Dispersion Modeling Of Continuous, Buoyant Air Pollution Plumes shown below:[5][6]


where:  
= crosswind dispersion parameter
  =
= vertical dispersion parameter =
= vertical dispersion with no reflections
  =
= vertical dispersion for reflection from the ground
  =
= vertical dispersion for reflection from an inversion aloft
  =
           
           
           
= concentration of emissions, in g/m³, at any receptor located:
            x meters downwind from the emission source point
            y meters crosswind from the emission plume centerline
            z meters above ground level
= source pollutant emission rate, in g/s
= horizontal wind velocity along the plume centerline, m/s
= height of emission plume centerline above ground level, in m
= vertical standard deviation of the emission distribution, in m
= horizontal standard deviation of the emission distribution, in m
= height from ground level to bottom of the inversion aloft, in m
= the exponential function

The above equation not only includes upward reflection from the ground, it also includes downward reflection from the bottom of any inversion lid present in the atmosphere.

The sum of the four exponential terms in converges to a final value quite rapidly. For most cases, the summation of the series with m = 1, m = 2 and m = 3 will provide an adequate solution.

and are functions of the atmospheric stability class (i.e., a measure of the turbulence in the ambient atmosphere) and of the downwind distance to the receptor. The two most important variables affecting the degree of pollutant emission dispersion obtained are the height of the emission source point and the degree of atmospheric turbulence. The more turbulence, the better the degree of dispersion.

Whereas older models rely on stability classes for the determination of and , more recent models increasingly rely on Monin-Obukhov similarity theory to derive these parameters.

Briggs plume rise equations

The Gaussian air pollutant dispersion equation (discussed above) requires the input of H which is the pollutant plume's centerline height above ground level. H is the sum of Hs (the actual physical height of the pollutant plume's emission source point) plus ΔH (the plume rise due the plume's buoyancy).

Visualization of a buoyant Gaussian air pollutant dispersion plume

To determine ΔH, many if not most of the air dispersion models developed between the late 1960s and the early 2000s used what are known as "the Briggs equations." G.A. Briggs first published his plume rise observations and comparisons in 1965.[7] In 1968, at a symposium sponsored by CONCAWE (a Dutch organization), he compared many of the plume rise models then available in the literature.[8] In that same year, Briggs also wrote the section of the publication edited by Slade[9] dealing with the comparative analyses of plume rise models. That was followed in 1969 by his classical critical review of the entire plume rise literature,[10] in which he proposed a set of plume rise equations which have become widely known as "the Briggs equations". Subsequently, Briggs modified his 1969 plume rise equations in 1971 and in 1972.[11][12]

Briggs divided air pollution plumes into these four general categories:

  • Cold jet plumes in calm ambient air conditions
  • Cold jet plumes in windy ambient air conditions
  • Hot, buoyant plumes in calm ambient air conditions
  • Hot, buoyant plumes in windy ambient air conditions

Briggs considered the trajectory of cold jet plumes to be dominated by their initial velocity momentum, and the trajectory of hot, buoyant plumes to be dominated by their buoyant momentum to the extent that their initial velocity momentum was relatively unimportant. Although Briggs proposed plume rise equations for each of the above plume categories, it is important to emphasize that "the Briggs equations" which become widely used are those that he proposed for bent-over, hot buoyant plumes.

In general, Briggs's equations for bent-over, hot buoyant plumes are based on observations and data involving plumes from typical combustion sources such as the flue gas stacks from steam-generating boilers burning fossil fuels in large power plants. Therefore the stack exit velocities were probably in the range of 20 to 100 ft/s (6 to 30 m/s) with exit temperatures ranging from 250 to 500 °F (120 to 260 °C).

A logic diagram for using the Briggs equations[5] to obtain the plume rise trajectory of bent-over buoyant plumes is presented below:

BriggsLogic.png
where:  
Δh = plume rise, in m
F  = buoyancy factor, in m4s−3
x = downwind distance from plume source, in m
xf = downwind distance from plume source to point of maximum plume rise, in m
u = windspeed at actual stack height, in m/s
s  = stability parameter, in s−2

The above parameters used in the Briggs' equations are discussed in Beychok's book.[5]

References

  1. J.C. Fensterstock et al, "Reduction of air pollution potential through environmental planning", JAPCA, Vol. 21, No. 7, 1971.
  2. C.H. Bosanquet and J.L. Pearson, "The spread of smoke and gases from chimneys", Trans. Faraday Soc., 32:1249, 1936.
  3. O.G. Sutton, "The problem of diffusion in the lower atmosphere", QJRMS, 73:257, 1947.
  4. O.G. Sutton, "The theoretical distribution of airborne pollution from factory chimneys", QJRMS, 73:426, 1947.
  5. 5.0 5.1 5.2 M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. .
  6. D. B. Turner (1994). Workbook of atmospheric dispersion estimates: an introduction to dispersion modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. .
  7. G.A. Briggs, "A plume rise model compared with observations", JAPCA, 15:433–438, 1965.
  8. G.A. Briggs, "CONCAWE meeting: discussion of the comparative consequences of different plume rise formulas", Atmos. Envir., 2:228–232, 1968.
  9. D.H. Slade (editor), "Meteorology and atomic energy 1968", Air Resources Laboratory, U.S. Dept. of Commerce, 1968.
  10. G.A. Briggs, "Plume Rise", USAEC Critical Review Series, 1969.
  11. G.A. Briggs, "Some recent analyses of plume rise observation", Proc. Second Internat'l. Clean Air Congress, Academic Press, New York, 1971.
  12. G.A. Briggs, "Discussion: chimney plumes in neutral and stable surroundings", Atmos. Envir., 6:507–510, 1972.

Further reading

  • M.R. Beychok (2005). Fundamentals Of Stack Gas Dispersion, 4th Edition. author-published. ISBN 0-9644588-0-2. 
  • K.B. Schnelle and P.R. Dey (1999). Atmospheric Dispersion Modeling Compliance Guide, 1st Edition. McGraw-Hill Professional. ISBN 0-07-058059-6. 
  • D.B. Turner (1994). Workbook of Atmospheric Dispersion Estimates: An Introduction to Dispersion Modeling, 2nd Edition. CRC Press. ISBN 1-56670-023-X. 
  • S.P. Arya (1998). Air Pollution Meteorology and Dispersion, 1st Edition. Oxford University Press. ISBN 0-19-507398-3. 
  • R. Barrat (2001). Atmospheric Dispersion Modelling, 1st Edition. Earthscan Publications. ISBN 1-85383-642-7. 
  • S.R. Hanna and R.E. Britter (2002). Wind Flow and Vapor Cloud Dispersion at Industrial and Urban Sites, 1st Edition. Wiley-American Institute of Chemical Engineers. ISBN 0-8169-0863-X. 